Combo

The Combo range of air cooled condensers generates the highest amount of power that can be transported in a container. Combo combines power and mobility, with excellent results.

Casing

The frame is designed to be stable and strong; overall dimensions designed for common means of ground transportation.
Fitted with a hot-dip galvanized IPE steel strengthener beam (S235JRH). (S.R.S. – Strain Relief System).
The fairing is made of hot-dip galvanized steel (DX51D-Z200MC to meet standard EN 10346).
All the operations involved in the production of the components are performed before painting, guaranteeing the highest level of protection for the steel against corrosion.
Epoxy powder coating (standard colour: RAL 9002) suitable for medium corrosive environments classified C3 (in accordance with EN 12944-2).
The side without inlets (U-bends) of the finned heat exchanger is protected by a panel fixed to the frame.
The fixings are all stainless steel (AISI 304, available on request: AISI 316).

Heat Exchangers

ROUND FINNED HEAT EXCHANGERS

The heat exchanger is built using copper tubes arranged in a staggered pitch and high efficiency aluminum fins (standard pitch: 2.1 mm).
The pressure vessel is designed for a PS = 10 bar and a TS = 110 °C in accordance with EC Pressure Equipment Directive 2014/68/EU. Testing was done with dry air.
The baffle plates are made of hot-dip galvanized steel (DX51D-Z200MC in accordance with EN 10346), while the sides are made of aluminum (alloy 1050-H24 in accordance with EN 573-3) to prevent damage to the pipes caused by thermal expansion.
The circuits are designed for counter flow and the copper headers are fitted with relief valves, drain valves and PN 10 loose flanges (in accordance with EN 1092) made of aluminum (EN AC-47000 in accordance with EN 1706); PN16 flange (EN 1092), class 150 (ASME B16.5) or stainless steel (AISI 304, AISI 316) available on request.

Fans

AC FANSETS

Maintenance-free, external rotor axial fans. Protective grid compliant with EN ISO 13857.
3-phase input, nominal voltage 400V (±10%), frequency 50Hz.
2 connection options: triangle (high speed) or star (low speed).
Insulation class F; built-in thermal contact; IP54 degree of protection (EN 60529).
Compliant with EC Standard EN 61800-5-1. Other homologation available on request.
Compliant with EC Directives 2006/95 LVD, 2009/125 ErP.
Power and sound pressure compliant with Standard EN 13487.
N.B.: the sound pressure level at a given distance is calculated in free field conditions, therefore it is merely indicative as it will be affected by the characteristics of the area where it is installed.

EC (ELECTRONICALLY COMMUTATED) FAN MOTORS – AXITOP DIFFUSER

Maintenance-free, external rotor axial fan motors. Protective grid compliant with EN ISO 13857. 3-phase input, nominal voltage 400V (±10%), frequency 50 / 60Hz.
Integrated PID control, RS485 MODBUS communications interface, volt-free contact for reading operating conditions and alarm states (motor and electronic overtemperature, mains voltage and phase failure, locked rotor protection), “”soft start”” function. Active analog output 10 VDC (max 10 mA).
Insulation class F; IP54 degree of protection (EN 60529).
Compliant with EC Standard EN 61800-5-1. Other homologation available on request.
Compliant with EC Directives 2004/108 EMC, 2006/95 LVD, 2009/125 ErP.
Power and sound pressure compliant with Standard EN 13487.
N.B.: the sound pressure level at a given distance is calculated in free field conditions, therefore it is merely indicative as it will be affected by the characteristics of the area where it is installed.
N.B.: EC electronic fans are not compatible with electrical systems with NEUTRAL isolated from ground (IT). Dedicated versions available on request.
AXITOP DIFFUSER
The diffuser installed on the delivery side of the fans partially recovers the dynamic pressure of the airflow producing the following benefits for the same global heat exchange capacity:
– reduction in fan rotation speed;
– global reduction in noise levels;
– reduction in electrical absorption.
or, keeping the noise levels unchanged, an increase in airflow and therefore also heat exchange capacity.

EC (ELECTRONICALLY COMMUTATED) FAN MOTORS

Maintenance-free, external rotor axial fans. Protective grid compliant with EN ISO 13857. 3-phase input, nominal voltage 400V (±10%), frequency 50 / 60Hz.
Integrated PID control, RS485 MODBUS communications interface, volt-free contact for reading operating conditions and alarm states (motor and electronic overtemperature, mains voltage and phase failure, locked rotor protection), “”soft start”” function. Active analog output 10 VDC (max 10 mA).
Insulation class F; IP54 degree of protection (EN 60529).
Compliant with EC Standard EN 61800-5-1. Other homologation available on request.
Compliant with EC Directives 2004/108 EMC, 2006/95 LVD, 2009/125 ErP.
Power and sound pressure compliant with Standard EN 13487.
N.B.: the sound pressure level at a given distance is calculated in free field conditions, therefore it is merely indicative as it will be affected by the characteristics of the area where it is installed.
N.B.: EC electronic fans are not compatible with electrical systems with NEUTRAL isolated from ground (IT). Dedicated versions available on request.

SRS

Strain Relief System.
Our exclusive system to stabilise the machine and avoid benging during all movements (lifting, transportation, installation) and over its entire life cycle.

 

Options & Accessories

ADIABATIC SYSTEMS

  • spray adiabatic systems
  • industrial adiabatic systems (pads)
  • ultraviolet lamp for adiabatic cooling system

PROTECTION COATINGS

  • pre-painted hydrophobic coating
  • pre-painted hydrophilic coating
  • thermoguard®
  • blygold®
  • electrofin®
  • heresite®
  • frame special colours

SPEED CONTROLLERS

  • standard speed regulator (triac)
  • inverter speed regulator frequency with sinusoidal filters installed
  • ec controller

WIRING

  • wiring and junction box
  • wiring in electrical panel with motor cutout (1 per fan)
  • electrical panel wiring
  • electrical panel wiring with built-in service switches (1 for every 2 fans)
  • electrical panel wiring with built-in service switches (1 per fan)
  • digital intelliboard

OPTIONAL COMPONENTS FOR WIRING

  • repair switches inside switchboard
  • repair switches installed close to the fan
  • motor protection units with thermocontacts
  • dual power switch

 

Applications